Radiofrequency ablation of rabbit liver : correlation between CT findings and pathological findings
The purpose of this study was to present the time-related imaging findings and correlative pathological findings of irradiated regions in the rabbit liver. RF ablation was carried out on 16 rabbit livers. Irradiated regions were imaged at 3 days, 4 weeks, and 12 weeks. At 3 days, the regions showed a two-zone structure on plain CT and peripheral enhancement on the arterial phase. The regions presented a three-zone structure on pathological study. At 4 weeks, peripheral enhancement had almost disappeared, and a two-zone structure obscured on plain CT. The CT findings reflected pathological changes after RF ablation.
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2001 |
---|---|
Erschienen: |
2001 |
Enthalten in: |
Zur Gesamtaufnahme - volume:61 |
---|---|
Enthalten in: |
Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica - 61(2001), 14 vom: 17. Dez., Seite 796-8 |
Sprache: |
Japanisch |
---|
Beteiligte Personen: |
Tsuda, M [VerfasserIn] |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 22.02.2002 Date Revised 24.11.2016 published: Print Citation Status MEDLINE |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLM117157104 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM117157104 | ||
003 | DE-627 | ||
005 | 20231222175917.0 | ||
007 | tu | ||
008 | 231222s2001 xx ||||| 00| ||jpn c | ||
028 | 5 | 2 | |a pubmed24n0391.xml |
035 | |a (DE-627)NLM117157104 | ||
035 | |a (NLM)11828758 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a jpn | ||
100 | 1 | |a Tsuda, M |e verfasserin |4 aut | |
245 | 1 | 0 | |a Radiofrequency ablation of rabbit liver |b correlation between CT findings and pathological findings |
264 | 1 | |c 2001 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a Date Completed 22.02.2002 | ||
500 | |a Date Revised 24.11.2016 | ||
500 | |a published: Print | ||
500 | |a Citation Status MEDLINE | ||
520 | |a The purpose of this study was to present the time-related imaging findings and correlative pathological findings of irradiated regions in the rabbit liver. RF ablation was carried out on 16 rabbit livers. Irradiated regions were imaged at 3 days, 4 weeks, and 12 weeks. At 3 days, the regions showed a two-zone structure on plain CT and peripheral enhancement on the arterial phase. The regions presented a three-zone structure on pathological study. At 4 weeks, peripheral enhancement had almost disappeared, and a two-zone structure obscured on plain CT. The CT findings reflected pathological changes after RF ablation | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Miyaji, H |e verfasserin |4 aut | |
700 | 1 | |a Ishibashi, T |e verfasserin |4 aut | |
700 | 1 | |a Shouki |e verfasserin |4 aut | |
700 | 1 | |a Takahashi |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica |d 1961 |g 61(2001), 14 vom: 17. Dez., Seite 796-8 |w (DE-627)NLM000053945 |x 0048-0428 |7 nnns |
773 | 1 | 8 | |g volume:61 |g year:2001 |g number:14 |g day:17 |g month:12 |g pages:796-8 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 61 |j 2001 |e 14 |b 17 |c 12 |h 796-8 |