Neodymium:YAG visual laser ablation of the prostate

OBJECTIVE: This study was performed to evaluate safety and efficacy of laser prostatectomy in the treatment of symptomatic benign prostatic hyperplasia (BPH).

METHODS: Neodymium:yttrium-aluminum-garnet (YAG) visual laser ablation of the prostate was performed in 43 patients (mean age 66 +/- 11.5 years) with BPH. The mean prostatic volume was 44.7 +/- 19.7 ml. A right-angle, side-firing laser fiber (Lasersonics Ultraline) and a neodymium:YAG laser generator (Hercules 5060) were used.

RESULTS: There were no perioperative complications including hemorrhage and transurethral reflux syndrome. The average postoperative hospital stay was 1.3 days, and the average urethral catheterization time was 3.8 days. Thirty-two patients were evaluated 6 months after the operation. A significant improvement was found in the mean symptom score from 21.8 +/- 7.6 to 8.3 +/- 6.9 (p < 0.001). A significant decrease from 104.3 +/- 78 to 55.7 +/- 30 ml was found between the preoperative and the postoperative mean residual urine volumes (p < 0.001). The mean peak flow rate increased from 8.7 +/- 3.9 to 16.1 +/- 2.4 ml/s (p < 0.001), and the mean average flow rate increased from 4.9 +/- 2 to 10.2 +/- 2.9 ml/s (p < 0.001).

CONCLUSION: Our results indicate that laser prostatectomy is a promising alternative in the treatment of BPH.

Medienart:

Artikel

Erscheinungsjahr:

1996

Erschienen:

1996

Enthalten in:

Zur Gesamtaufnahme - volume:29

Enthalten in:

European urology - 29(1996), 4 vom: 29., Seite 446-9

Sprache:

Englisch

Beteiligte Personen:

Sengör, F [VerfasserIn]
Erdoğan, K [VerfasserIn]
Tuzluoğlu, D [VerfasserIn]
Onur, S [VerfasserIn]
Erol, A [VerfasserIn]
Sözer, T [VerfasserIn]

Themen:

Journal Article

Anmerkungen:

Date Completed 20.11.1996

Date Revised 26.08.2019

published: Print

Citation Status MEDLINE

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM087624710