High-performance liquid chromatography – atmospheric pressure negative chemical ionisation – mass spectrometry of 2,4-dinitrophenyl derivatives of amines
Abstract High-performance liquid chromatography (HPLC) coupled to mass spectrometry (MS) is used to detect 2,4-dinitrophenyl (DNP) derivatives of amines by means of negative chemical ionisation at atmospheric pressure. The high sensitivity and good comparability of UV- and MS-detection of DNP-derivatives of amines is shown by several examples. The high selectivity of the derivatisation and the detection method (UV and MS) is used for the analysis of unknown amines in aqueous phases after hydrolytic degradation of polyamide-amine- or polyamine-epoxide-adducts as well as for the characterisation of commercial products..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
1996 |
---|---|
Erschienen: |
1996 |
Reproduktion: |
Springer Online Journal Archives 1860-2002 |
---|---|
Enthalten in: |
Zur Gesamtaufnahme - volume:356 |
Enthalten in: |
Fresenius' Zeitschrift für analytische Chemie - 356(1996) vom: Aug., Seite 495-499 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Fuchslueger, U. [Sonstige Person] |
---|
Links: |
---|
Umfang: |
5 |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
NLEJ20182860X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ20182860X | ||
003 | DE-627 | ||
005 | 20230506143800.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070527s1996 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ20182860X | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a High-performance liquid chromatography – atmospheric pressure negative chemical ionisation – mass spectrometry of 2,4-dinitrophenyl derivatives of amines |
264 | 1 | |c 1996 | |
300 | |a 5 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Abstract High-performance liquid chromatography (HPLC) coupled to mass spectrometry (MS) is used to detect 2,4-dinitrophenyl (DNP) derivatives of amines by means of negative chemical ionisation at atmospheric pressure. The high sensitivity and good comparability of UV- and MS-detection of DNP-derivatives of amines is shown by several examples. The high selectivity of the derivatisation and the detection method (UV and MS) is used for the analysis of unknown amines in aqueous phases after hydrolytic degradation of polyamide-amine- or polyamine-epoxide-adducts as well as for the characterisation of commercial products. | ||
533 | |f Springer Online Journal Archives 1860-2002 | ||
700 | 1 | |a Fuchslueger, U. |4 oth | |
700 | 1 | |a Rissler, K. |4 oth | |
700 | 1 | |a Grether, H. -J. |4 oth | |
700 | 1 | |a Grasserbauer, M. |4 oth | |
773 | 0 | 8 | |i in |t Fresenius' Zeitschrift für analytische Chemie |d 1947 |g 356(1996) vom: Aug., Seite 495-499 |w (DE-627)NLEJ188989293 |w (DE-600)2235442-6 |x 1618-2650 |7 nnns |
773 | 1 | 8 | |g volume:356 |g year:1996 |g month:08 |g pages:495-499 |g extent:5 |